Searching: SHD511P5UCMS
Nominal range of press. difference | ± 3kPa to ±100kPa * |
---|---|
Max. common mode pressure | 10 x Pdif nominal |
Max. overpressure | 20 x Pdif nominal |
Sampling frequency | 2,5Hz (25Hz) |
Error | max. 1% |
Zero temperature error | typ. 0,1% max. 0,3 %/10°C |
Span temperature error | typ. 0,1% max. 0,3 %/10°C |
Operating temp. range with display . | -20 ÷ +85°C -20 ÷ +70°C (non condensing) |
Media temperature | -25 ÷ 100°C |
Storage temperature with display | -25 ÷ 100°C -25 ÷ 80°C |
Supply voltage | 5 ÷ 36V dc |
Supply current | typ. 4mA |
Output | 4 ÷ 20mA two-wire 0 ÷ 20mA three-wire 0 ÷ 10V three-wire 0 ÷ 3V three-wire RS232 four-wire RS485 four-wire USB four-wire open collector three-wire relay four-wire |
Operating position | arbitrary |
Protection | min. IP 65 |
Voltage endurance | min. 1000V ss |
Weight | cca 350g |
* pressure difference can be increase to max. common pressure mode level by software
ČSN EN 61326-1
Transmitters are connected into electrical circuit by common way. They are protected against supply reversing polarity by series diode. ATTENTION with more-wire connection, when for example changing output and supply wire may cause transmitter damage.
Detailed description all types of electrical connections, pin assignments and protocol description for series communication are in special document, which is a part of transmitter delivery.
Conector | 3 | 2 | 1 | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Screw terminal | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
4 ÷ 20mA | +Ucc | -Ucc | case | |||||||
0÷20mA | +Ucc | -Ucc | Out | case | ||||||
0÷10V | +Ucc | -Ucc | Out | case | ||||||
0÷3V | +Ucc | -Ucc | Out | case | ||||||
RS232 | +Ucc | -Ucc | RxD | TxD | case | |||||
RS485 | +Ucc | -Ucc | B | A | case | |||||
Switching outputs | Re1 | Re2 | OK1 | OK2 |