link mail
Contact
linkedIn
Download

Searching: TMVG438M2E


  • small dimensions

  • overpressure endurance

  • simple application

  • supply voltage 5 V

  • low power consumption

M - miniature pressure transmitter - NOT AVAILABLE

Basic technical information of pressure transmitter

Nominal pressure range± 10kPa to ± 1MPa
Overpressure to 40kPa
over 60 kPa
100 kPa
200 % nominal range
Errormax. 1,5% (1%)
Zero temperature errortyp. 0,2%
max. 0,3 %/10°C
Span temperature errortyp. 0,2%
max. 0,3 %/10°C
Compensated temp. range0 ÷ +70°C
Operating temp. range-15 ÷ +85°C (non condensing)
Storage temperature-25 ÷ 100°C *
Supply voltage5 ÷ 15V dc
Supply currenttyp. 0,5mA
Output0,5 ÷ 4,5V *
Operating positionarbitrary
Protectionmin. IP 54
Weightcca 35g

At the customer´s wish it is possible to secure a metrological verification of the transmitters at an accredited Calibration Service Centre.

Instructions for use

  • Before the transmitter is connected to the pressure circuit it is necessary to check whether the measured pressure corresponds with the nominal range of the transmitter. Even a short-time overload over the maximum permissible overpressure can cause destruction of the measuring membrane.
  • In case of using other media than air, nitrogen, water, oil, ethyl alcohol it is necessary to check the resistance of the materials, see the front page
  • For the transmitter sealing it is recommended to use “O” ring 12x2, supplied with the transmitter. While sealing to the thread (Teflon, tow) for liquid media, it is necessary to pay high attention to caution because screwing into closed volume of liquid can cause increase of pressure and destruction of the membrane!
  • Caution when sealing of thread (with teflon or with oakum) in liquid medium, because of screwing into the closed volume of liquid can cause uncontrollable rise of pressure and destroy this way meassuring membranes!

Diagram

Diagram

Pin assignmentsvalid for connector DIN 43650 C

 voltage output
+ supply voltage3
- supply voltage2
output1
shielding

Dimensions of pressure transmitter

Dimensions of pressure transmitter
LinkedIN
copyright 2010 cressto.cz | Sitemap | Portfolio |