Searching: TM G517C3F


  • high chemical resistance

  • simple application

  • universal usage

  • high stability

  • favourable price

A - pressure transmitter with ceramic measuring membrane

Basic technical information of pressure transmitter

Nominal pressure range0÷10kPa to 0÷60MPa
Overpressure200% (400%) nominal range
Errormax. 1% (0.5%)
Zero temperature errortyp. 0,1
max. 0,3 %/10°C
Span temperature errortyp. 0,1
max. 0,3 %/10°C
Compensated temp. range20 ÷ +85°C
Operating temp. range-15 ÷ +85°C (non condensing)
Storage temperature-25 ÷ 100°C
Supply voltage12 ÷ 36V dc
Supply voltage – output H< 4mA
Output4 ÷ 20mA two-wire
0 ÷ 20mA three-wire
0 ÷ 10 V three-wire
Operated positionarbitrary
Protectionmin. IP 54
Voltage strength
case - electronics
min. 1000 V dc
Weightcca 200g

EMC – according to ČSN EN 61326-1
At the customer´s wish it is possible to secure a metrological verification of the transmitters at an accredited Calibration Service Centre.

Instructions for use

  • Before connection of the transducer into the pressure circuit, it is necessary to verify that the pressure being measured corresponds to the nominal range of this transducer. Even a transient loading over the maximum allowable overpressure may cause a destruction of the measuring diaphragm!
  • Measured media is in contact with stainless steel, Viton sealing and ceramic membrane. If you use aggressive media, it is necessary to verify the transducer material resistance.
  • Transmitter with open membrane must be sealed by the “O” ring on six-edge surface to avoid mechanical strain in sensor fitting.
  • In the case of turning-off with connector nut you must avoid to turning of connector base ! In opposite case input wires can be ruptured !
  • The device requires no maintenance during operation. Potential reparation performs manufacturer. Device will be electronic waste after end of its usage. The user is obliged to guarantee liquidation of device in accordance with a valid prescription at the liquidation time. It is recommended deliver device to authorised person.

Diagram

Diagram

Pin assignmentsvalid for connector DIN 43650

 two-wire
4 ÷ 20mA
three-wire
0 ÷ 20mA
three-wire
0 ÷ 10V
+ supply voltage133
- supply voltage222
output 11
shielding

Dimensions of pressure transmitter

Dimensions of pressure transmitter