Basic technical information of pressure transmitter
Type
DMS01
DMS1
DMS10
DMS100
DMS1000
Measuring pressure range
±200 Pa
±2 kPa
±20 kPa
-100÷200 kPa
-100÷2000 kPa
Overpressure max.
1 kPa
10 kPa
40 kPa
300 kPa
2000 kPa
Burst pressure
20 kPa
100 kPa
100 kPa
400 kPa
3000 kPa
Error
max. 1%
max. 0,5%
max. 0,5%
max. 0,5%
max. 0,5%
Type of pressure measurement
Differential
Differential
Differential
Differential/absolute
Relative
Pressure connection
Nipple for a quick coupler 5mm
Ambient temperature range
0 ÷ +50°C (non condensing)
Storage temperature
-5 ÷ 55°C
Protection
IP 41
Supply
2x AA battery or accumulator
Current consumption
50mA with backlight, 10mA without backlight
Max. charging current
450mA
Outside dimensions
145 x 85 x 35 mm
Weight(with battery)
285g
EMC – accords to ČSN EN 61326-1 At the customer´s wish it is possible to secure a metrological verification of the meters at an accredited Calibration Service Centre.
Instructions for use
Before the gauge is connected to the pressure circuit, it is necessary to secure that the pressure range of the device corresponds with the measured pressure. With the differential gauge, the user must secure that the measuring membrane is not unilaterally overloaded by pressure that is higher than the permitted non-destructive pressure, corresponding with the nominal range.
It is also necessary to check whether the measured media does not attack the used materials, which are silicon, duralumin, brass, polyetherimid plastic and fluorosilicon sealing. Air, nitrogen, water, ethanol, oils, etc. meet this requirement.