Searching: TM G448N3GJBI
Nominal pressure range | ± 100Pa to ± 100kPa |
---|---|
Overpressure to 2kPa from 2kPa to 20 kPa from 20kPa to 100 kPa over 100 kPa | 20 kPa 50 kPa 300 % nominal range 200 % nominal range |
Error | max. 1% (0.5%) ± 2Pa |
Zero temperature error | typ. 0,2% max. 0,3 %/10°C |
Span temperature error | typ. 0,2% max. 0,3 %/10°C |
Compensated temp. range | 20 ÷ +70°C |
Operating temp. range | -20 ÷ +60°C (non condensing) |
Storage temperature | -25 ÷ 100°C |
Supply voltage - output F,G | 10 ÷ 24V dc |
Supply voltage - output H | 8,5 ÷ 22V dc |
Supply current - output G,H | typ. 4.5 mA |
Output | 4 ÷ 20mA two-wire 0,2 ÷ 1mA three-wire 0,05 ÷ 1V three-wire |
Operated position | arbitrary |
Protection | min. IP 65 |
Weight | cca 400g |
I M1 Ex ia I
II1G Ex ia IIB T4 Ga
II 1D Ex ia IIIC T135°C Da
Barometric transmitters are produced with standard range 80 ÷ 120 kPa.
At the customer´s wish it is possible to secure a metrological verification of the transmitters at an accredited Calibration Service Centre.