link mail
Contact
linkedIn
Download

Searching: KTNA528H


  • very high sensitivity

  • overpressure endurance

  • small dimensions

  • wide temperature range

  • vibration endurance

  • damping time constant selection

KTN - pressure module

Basic technical information of pressure transmitter

Nominal pressure range± 50Pa to ± 100kPa
Overpressure to 2 kPa
from 2 kPa to 20 kPa
from 20 kPa to 100 kPa
20 kPa
50 kPa
300 % nominal range
Errormax. 1% ± 2Pa
Zero temperature errortyp. 0,2%
max. 0,3 %/10°C
Span temperature errortyp. 0,2%
max. 0,3 %/10°C
Compensated temp. range0 ÷ +70°C
Operating temp. range-20 ÷ +85°C (non condensing)
Storage temperature-25 ÷ 100°C
Supply voltage12 ÷ 36V dc
Supply current - output H< 4mA
Output4 ÷ 20mA two-wire
0 ÷ 20mA three-wire
0 ÷ 10 V three-wire
Operated positionarbitrary
ProtectionIP 00
Weightcca 20g
Common-mode pressure for
differential version
max. 100 kPa

Barometric transmitters are produced with standard range 80 ÷ 120 kPa.

Instructions for use

  • Before connection of the module into the pressure circuit, it is necessary to verify that the pressure being measured corresponds to the nominal range of this transducer. Even a transient loading over the maximum allowable overpressure may cause a destruction of the measuring diaphragm!
  • If you measure a pressure of such media which are not non-aggressive gases, it is necessary to verify the transducer material resistance.
  • The manufacturer is not responsible for damages caused by improper installation.

Diagram

Diagram

Pin assignments

 two-wire
4 ÷ 20mA
three-wire
0 ÷ 20mA
three-wire
0 ÷ 10V
+ supply voltage111
- supply voltage222
output 33
shielding4,54,54,5

Dimensions of pressure transmitter

Dimensions of pressure transmitter

Adjusting elements

Time damping

F1OFFOFFONON
F2OFFONOFFON
τ [s]0123